Bump Test

To start this test, we configure the Trigger for the channel you wish to use, in this example Channel 1:

  • go to the Menu top bar and select “Tools”
  • then “Preferences”
  • and “Channels”

The checkbox for Channel 1 must be selected. You can choose more than 1 channel if you want to activate the Trigger with other sensors.
Default trigger level is set at 1 mm/s but if the vibration is already high because other machines are nearby, then increase this value to the level where the Trigger is activated when you need it.

Start a New Analysis with 1 channel.
Depending on the interface (2-channel or 4-channel) and how many vibration sensors are already placed in other directions, select more channels:

Select the recording time (in this example 5 seconds). To launch the trigger recording click :

You are ready now.

Click on the Trigger recording button and you can see that the system is working and waiting the bump because:

  • the left column shows measurements of small vibrations where the sensor is placed
  • the graphics in time-domain and FFT are updating
  • there is no decreasing counter on the right of the recording time selector


Hit the structure with a rubber hammer in a rapid movement and notice the decreasing counter starting
Let the vibration attenuate by itself until the end of the recording or stop the recording manually:

On the time domain graph, zoom-in the interesting zone avoiding the bump impact zone.
Left-click-and-hold in one zone and drag to another zone in the graph:

The resonant frequency of the structure you just hit (right-click on FFT graph for markers) is at 1332.53 CPM:

This test can be done placing the sensor in different directions or hitting the structure on other places and checking the results that can be very useful too to eliminate resonant frequencies that could lead to potential damage to the structure.

If you have any question, please contact us.

Carlos Varguez

Recent Posts

UADY Congress

Building Tomorrow: Inspiring Future Engineers at UADY On October 9th, 10th, and 11th, Erbessd Instruments…

1 month ago

Vibration Beating

Understanding Vibration Beating in Vibration Analysis and Balancing In vibration analysis and balancing, certain phenomena…

1 month ago

Erbessd at the CMC Event 2024

On September 4th and 5th, we had the privilege of participating in the CMC Mexico event, held…

2 months ago

Is Your Vibration Diagnostic System a Black Box or a White Box?

Is Your Vibration Diagnostic System a Black Box or a White Box? - The Case…

3 months ago

Phantom of the Thames: Five Years of Wireless Condition Monitoring by Erbessd-Instruments

Phantom of the Thames: Five Years of Wireless Condition Monitoring by Erbessd-Instruments The history of…

4 months ago

Remote monitoring in predictive maintenance: Improving Machine Health

Optimize machine performance with remote monitoring and predictive maintenance. Reduce downtime, enhance productivity, and extend…

6 months ago