GATEWAY 2.0 ENHANCED REPEATER NETWORK

REPEATER SETTINGS USING GATEWAY 2.0 With the introduction of firmware version 52 for the Phantom Gateway 2.0, we’ve added a new feature to streamline multi-gateway deployments. This new functionality can be utilized in two ways: Through the Gateway’s Wi-Fi mesh network or via the existing network (Wi-Fi or Ethernet). SUBORDINATES USING THE GATEWAYS WI-FI MESH NETWORK … Weiterlesen

New Auto-diagnosis Tool

Auto-diagnosis tool Vibration analysis in a single touch. Learn how to use our new diagnosys tool; swiftly and accurately detects vibration anomalies, diagnosing potential machinery issues before they escalate. 1. What is the Auto-diagnosis tool for? This is an analysis tool offered by EI-Analytic. That functions as a breakdown of possible failures at the analyzed … Weiterlesen

Phantom Sensors Gateway 2.0 Configuration

Phantom Sensors with Gateway 2.0 Learn how to create the connection between Phantom sensors and the most powerful gateway. If you have not yet configured your gateway 2.0 to send data anywhere; find two tutorials, which will help you to connect the Gateway to EI-Analytic or EI-Monitoring. Pair Phantom sensors with Gateway 2.0 When your … Weiterlesen

EI Monitoring Gateway 2.0 Connection

EI Monitoring WITH Gateway 2.0 Learn how to create the connection between EI Monitoring Service and the most powerful gateway. Enable internet connection First of all is important to connect our Gateway 2.0 to a network. This can be done in one of two ways: Connect the Gateway directly to the modem using an ethernet … Weiterlesen

EI Analytic Gateway 2.0 Configuration

EI Analytic with Gateway 2.0 Learn how to create the connection between our cloud service and the most powerful gateway. Enable internet connection First of all is important to connect our Gateway 2.0 to a network. This can be done in one of two ways: Connect the Gateway directly to the modem using an ethernet … Weiterlesen

How to create an SCADA Scheme?

How to create an SCADA squeme on EI-Analytic? In the following manual, you will learn how to use EI-Analtyicâ„¢’ new tool, SCADA schemes. First, log in from your EI-Analtyicâ„¢ account, then go to the Database tab and click on SCADA: Now, you will see the following menu with these options: 1- New Scheme: allows you … Weiterlesen

Firmware Update and Channel Change

WiSERâ„¢ 3X Firmware Update Tool This new WiSER 3X firmware update allows you to change the Wi-Fi channel that the sensor uses. In some networks, the channels may be occupied by other applications or have a lot of data traffic, causing the WiSERâ„¢ 3X to disconnect from your DigivibeMX® software or WiSERâ„¢ Vibe Pro app. … Weiterlesen

Problemas Comunes con GX-400

GX400 Problemas conocidos Hemos construido la interfaz GX400 de Erbessd Instruments con la mejor tecnología. Esto para asegurar una comunicación eficiente y fácil entre sus acelerómetros, sensores ópticos y DigivibeMX. Sin embargo, hay algunas dificultades conocidas que pueden causar problemas con la primera instalación. Aquí, le mostraremos cómo resolver estos problemas de forma temprana. Configuración … Weiterlesen

Resolution Points, Max Frequency and Bearings

Resolution Points, Max Frequency and Bearings To increase the number of Resolution points (lines) there are 2 methods: increase the Sample Rate (with old interfaces i400-i500-i600-i800) increase the Recording Time (only method available for GX400 4 channel interface) To increase the Max Frequency, there is 1 method: increase the Sample Rate, select “Setup” and “Config” … Weiterlesen

ODS Simulation

ODS Simulation For 3D ODS simulation, the measurements need to be taken on an Analysis Routine using 2 accelerometers, 1 accelerometer is moved from one point to the next (channel 1) and the 2nd accelerometer is placed in one part of the machine in the same position where vibration from the machine can be measured, … Weiterlesen