Articles

Acceleration Enveloping for Bearing Fault Analysis

Acceleration Enveloping for Bearing Fault Analysis

Table of Contents

Continuing to do the same thing while expecting a different result.

As problems occur with rotating equipment the vibration analysis professionals of the world typically leap into action. Taking data, analyzing that data and drilling down to the root cause of the problem. Without acceleration enveloping equipment owners will likely first become aware of damage to the bearing by seeing an increase in overall vibration, and in some cases a rise in temperature. At this point in the failure the damage is more likely to be extensive than if the bearing faults were identified earlier in the P-F curve. In the very worst case scenarios collateral damage has likely already occurred and the equipment will have already experienced one, if not many different failure modes… or even functional failure.

How Acceleration Enveloping Works

Acceleration enveloping is an incredibly powerful tool for vibration analysts and in many ways is superior to competing methods. Acceleration enveloping is a multi-step process that ERBESSD-INSTRUMENTS and our award winning DigivibeMX software has automated to make bearing analysis easier. To understand how DigivibeMX handles this it is important to first understand the basics.

With Acceleration Enveloping we should first apply a band pass filter to the mix of low and high frequencies of a defective bearing’s unfiltered waveform. This will isolate only the bearing fault frequencies from within the signal that was collected. The filtered output generally identifies repeating high frequency data. This is often represented as a series of spiking energy bursts. These spikes/peaks are the impact of the rolling elements ringing down after coming into contact with the defect within the bearing.

Next we must pass the filtered output through an enveloping algorithm which then rectifies (demodulates) the waveform by inverting the negative part to the positive to create more density and then extracts the repetition rate of the energy spikes. This new enveloped signal helps the fault frequencies present and stand out from all other energy. The envelope assists in containing regularly spaced energy spikes such as an inner race or outer race defect. Acceleration Enveloping is a great tool for synchronous energy analysis as the envelope helps contain and identify the regularly spaced synchronous peaks.

DigivibeMX’s band pass filter range is 10x the RPM value specified in the Machine Point Defininition. This is why an RPM value must be specified when setting up the Machine Points. If the RPM is 0 or no RPM was specified, the band pass filter would be 0-10,000 CPM.

  • DigivibeMX first removes low frequencies below 10XRPM with an FFT
  • Next the FFT is inverted
  • Then DigivibeMX converts all negative values to positive to maximize density
  • Next the envelope is applied by joining all the top points of the curve
  • Lastly, we calculate the resulting FFT for analysis

Key Considerations

It is critical to understand that as with all vibration analysis some skill and experience are needed to interpret the data. Sometimes amplitude will decrease as a bearing fails, which could be missed by a novice analyst, whereas the experienced analyst might recognize this type of behavior and realize the imperfection may have simply smoothed out with wear and the bearing is actually still riding the P-F Curve toward functional failure.

About the author

Dr. Michael Howard, is an American entrepreneur and Air Force veteran with a remarkable career in the predictive maintenance industry spanning over 30 years, and a variety of industrial sectors, including industrial manufacturing, reliability engineering, and instrumentation development and design organizations. Dr. Howard is a graduate of Excelsior University, Capella University, and New Charter University with degrees in Electro-Mechanical Engineering, Leadership and Organizational Management, and Engineering Management.

As the CEO of Erbessd Instruments, he leads strategy, sales, marketing, and operations in English-speaking markets. He is a certified reliability engineer, certified maintenance and reliability professional, and category III vibration analyst.  Michael is a passionate advocate for wireless instrumentation, video deflection, and the Industrial Internet of Things (IIoT).

ERBESSD INSTRUMENTS® is a leading manufacturer of Vibration Analysis Equipment, Dynamic Balancing Machines, and Condition Monitoring with facilities in Mexico, the USA, the United Kingdom, and India.

EI Admin

Recent Posts

UADY Congress

Building Tomorrow: Inspiring Future Engineers at UADY On October 9th, 10th, and 11th, Erbessd Instruments…

1 month ago

Vibration Beating

Understanding Vibration Beating in Vibration Analysis and Balancing In vibration analysis and balancing, certain phenomena…

1 month ago

Erbessd at the CMC Event 2024

On September 4th and 5th, we had the privilege of participating in the CMC Mexico event, held…

2 months ago

Is Your Vibration Diagnostic System a Black Box or a White Box?

Is Your Vibration Diagnostic System a Black Box or a White Box? - The Case…

3 months ago

Phantom of the Thames: Five Years of Wireless Condition Monitoring by Erbessd-Instruments

Phantom of the Thames: Five Years of Wireless Condition Monitoring by Erbessd-Instruments The history of…

4 months ago

Remote monitoring in predictive maintenance: Improving Machine Health

Optimize machine performance with remote monitoring and predictive maintenance. Reduce downtime, enhance productivity, and extend…

6 months ago